Environmental specifications
Specification |
Value |
---|---|
Temperature range* |
— |
Operating |
10°C to 35°C (50°F to 95°F) |
Non-operating |
-30°C to 60°C (-22°F to 140°F) |
Relative humidity (noncondensing)** |
— |
Operating |
10% to 90% @ 28°C (82.4°F) |
Non-operating |
5% to 95% @ 38.7°C (101.7°F) |
Altitude† |
— |
Operating |
3050 m (10,000 ft) |
Non-operating |
9144 m (30,000 ft) |
* The following temperature conditions and limitations apply:
- All temperature ratings shown are for sea level.
- An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) up to 3048 m (10,000 ft) applies.
- No direct sunlight is allowed.
-The maximum permissible rate of change is 10°C/hr (18°F/hr).
- The type and number of options installed may reduce the upper temperature and humidity limits.
- Operating with a fan fault or above 30°C (86°F) may reduce system performance.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F).
†Maximum storage altitude corresponds to a minimum pressure of 70 kPa (10.1 psia).