Environmental specifications

Specification

Value

 

Temperature range*

Operating

10°C to 35°C (50°F to 95°F)

Non-operating

-30°C to 60°C (-22°F to 140°F)

Relative humidity (noncondensing)**

Operating

10% to 90% @ 28°C (82.4°F)

Non-operating

5% to 95% @ 38.7°C (101.7°F)

Altitude†

Operating

3050 m (10,000 ft)

Non-operating

9144 m (30,000 ft)

* The following temperature conditions and limitations apply:

- All temperature ratings shown are for sea level.

- An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) up to 3048 m (10,000 ft) applies.

- No direct sunlight is allowed.

-The maximum permissible rate of change is 10°C/hr (18°F/hr).

- The type and number of options installed may reduce the upper temperature and humidity limits.

- Operating with a fan fault or above 30°C (86°F) may reduce system performance.

** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F).

†Maximum storage altitude corresponds to a minimum pressure of 70 kPa (10.1 psia).

Environmental specifications